Mfg Part Number: HY2511 2 | Alternate P/N: HY25112 | NSN : 5950-00-419-5285 |
NIIN : 004195285 | CAGE Code : 29525 | Manufacturer: Hytronics Corp |
Item Name : Transformer Power | FSC : 5950 Coils and Transformers |
Nascent Industrial is your one-stop shop for top quality part HY2511 2 under NSN 5950-00-419-5285, that of which is listed with the description “Transformer Power.” With the NSN part number HY2511 2, this particular NSN Part was manufactured by Hytronics Corp. If you are interested in this item, we have current availability and encourage you to utilize the form provided to you below to request a quote for your comparisons with ease. With the various details that you submit, our team members will formulate a customized solution that caters to your requirements. To ensure that your procurement process is efficient and quick, we guarantee responses to quote requests within 15 minutes of receiving a completed form.
To make certain that customers procure the exact items that they need, we list products alongside all relevant information. For instance, this Hytronics Corp NSN part HY2511 2 was specifically produced under the CAGE Code 29525. Additionally, all items ship out alongside their qualifying certifications and manufacturing trace documentation, as applicable. Due to our peerless dedication to quality control and export compliance, we conduct business with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you are ready to procure NSN 5950-00-419-5285 or simply want more information on what we can do for you, get in touch with a representative at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-419-5285 Item Description: TRANSFORMER,POWER | 5950 | 004195285 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PEI 6789 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 2.313 INCHES NOMINAL2.313 INCHES NOMINAL2.313 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.750 INCHES NOMINAL1.750 INCHES NOMINAL1.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.750 INCHES NOMINAL1.750 INCHES NOMINAL1.750 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 95.0 DEG CELSIUS95.0 DEG CELSIUS95.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 10.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY30.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY30.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 9 SOLDER STUD |
![]() |